Out of Stock

STANDARD charging station (socket)

 845,00 ex.VAT

SMART charging station designed for 1-phase or 3-phase Mode 3 electric vehicle charging with currents up to 16 A (3,7 – 11 kW).

Specification:

  • 3,7 kW or 11 kW
  • Adjustable charging current
  • Wired dynamic load balancing DLM
  • Type 2 socket
  • Metal enclosure with tempered glass front
  • WiFi connectivity
  • Integrated RCCB Type A 30 mA AC + 6 mA DC
  • Metron Charge Control WiFi software: solar surplus charging, house main fuse protection, hourly power regulation, charging based on energy stock prices, and many other advanced functions  
  • Metron Device Access for remote control
  • WiFi Modbus for integration with home assistants
  • Adjustable charging current
  • IP54 and IK10
  • 3-year warranty
  • Made in Slovenia

PLEASE NOTE: The displayed price is for the above configuration; the price will differ with added features. For a different configuration, please see the list of additional features below.


   Navodila za uporabo – SI
   User manual – ENG
Complete Quick Installation Guide for Installers – ENG
Brochure – ENG


Manufactured on order, please request a quote.


Request a quote

Manufactured on order

Description

Additional features not included in the base price:

  • Different power: 7,2 kW or 22 kW
  • Switching between 1-phase and 3-phase charging (only with 3-phase versions)
  • OCPP 1.6J communication for commercial marketing of charging services
  • MID-certified energy meter
  • ISO 15118 High-level communication module with AutoCharge automatic  vehicle charging authorization and future V2G capability
  • RFID reader for ISO/IEC 14443A compatible MIFARE cards/tags
  • LED display resistant to high temperatures and direct solar irradiation
  • Customizable (optional): custom laser engraving on the front panel (for example, company logo, etc.) and enclosure can be coated in custom paint color (with larger orders)
  • Tesla charge port opener and unlocker button
  • Wireless dynamic load management DLM with additional 3FD-3 module

General Technical Specifications:

  • Socket Type (Station Side): Type 2 (IEC 62196)
  • Adjustable charging curent: 6A, 8A, 10A, 13A, 16A for 3,7 – 11 kW and 20A, 25A or 32A for 7,4 – 22 kW
  • Rated Voltage (single/three phase): 230/400V
  • Operating voltage range: from 180 V up to 270 V (phase voltage) / 50 Hz
  • Micro EVSE – in-house developed  vehicle communication module
  • User info via RGB LED O-ring and optional LED display
  • Two applications for monitoring and control
  • Metron Dynamic load balancing (DLM)
  • Modbus TCP/IP support
  • Future-proof OTA (over-the-air) firmware updates
  • Supported Wi-Fi standards: IEEE 802.11b/g/n
  • Wi-Fi speed: up to 150 Mbit/s
  • Wi-Fi security: WPA2
  • Wi-Fi signal range: up to 20 m
  • Over-current protection: 1 or 3-phase circuit breaker C20A or C40A (10kA short-circuit breaking capacity) including additional independent numerical (software) overcurrent protection (acts on charging contactor)
  • Built-in ground fault protection device (RCD): RCCB Type A 30mA AC + 6mA DC or RCCB Type B (10kA short-circuit breaking capacity)
  • UV, oil and flame resistant cable insulation
  • Operating Ambient Air Temperature Range: -30 °C to +50 °C
  • IP Rating: IP54
  • IK rating: IK10
  • Dimensions (H x W x D): steel enclosure: 340 mm x 240 mm x 100 mm
  • Weight: approx. 8-10 kg (depending on the charging cable length)
  • IEC 61851 compliant
  • CE approved

Pricing:

For the correct price of a unit with the features you require, please contact us with a quote request.

Contact us for more information



Modbus TCP/IP communication

Charging stations support Modbus TCP/IP communication protocol, which enables third-party home automation systems to monitor and control each charging station connected to a local Wi-Fi network. Modbus MASTER device can read real-time charging power, current, voltage and charging energy information from the charging station as well as set the charging current. Required Metron MODBUS TCP/IP REGISTER TABLE is available for download here: Metron MODBUS TCP/IP REGISTER TABLE

Over-the-air (OTA) software update

OTA update can be performed by any user via internet, using Metron Device Access application. The update process is fully automated and requires charging station to have internet access via Wi-Fi.

NOTE: Older versions of our smart charging stations can also be upgraded to gain all the latest features. Please contact us for further instructions.

Green production

All our products are produced in a carbon-neutral way by using the “Sustainable energy cycle” method. The production plant where we make charging stations is the first fully sustainable production facility. All energy needed for the heating and cooling of the building, production process and for transportation of goods and employees (except deliveries of heavy materials by trucks), is produced by photovoltaic power plants and stored in storage batteries. Almost all of the raw materials we use are produced in EU, to shorten supply routes and support the local economy. Buying our products helps develop a sustainable economy.

Compatibility

100% compatible with all electric vehicles.

What is RCD and how does it work

RCD is an acronym for Residual Current Device – sometimes it can be called an Earth Leakage Circuit Breaker or Safety Switch. Its purpose is to prevent you from getting a fatal electric shock if you touch a live part, such as a bare copper wire under high voltage. RCDs offer a level of personal protection that ordinary fuses/circuit-breakers cannot provide. RCD constantly monitors the electric current flowing through one or more circuits that it protects. If it detects electricity flowing down an unintended path, such as through a person who has touched a live part, the RCD will switch the circuit off very quickly, significantly reducing the risk of death or serious injury. Every charging station comes with an integrated Type A 30mA AC + 6mA DC RCD  or Type B RCD, which ensures the maximum possible level of personal protection as it protects users from AC, pulsating DC and pure DC leakage currents.

Additional information

Charging Power

1-phase 16A (3,7 kW), 1-phase 32A (7,4 kW), 3-phase 16 A (11.1 kW), 3-phase 32 A (22.2 kW)

Dynamic Power Control

Optional (wired or wireless)

Independent weekly timer

Optional

MID certified kWh

Optional, a kWh counter is also present in the Metron Charge Control app

RF remote control

Optional

RFID

Optional



Exclusive products